Reconstruction of radiometric system "ERIDAN"
Transactions of IAA RAS, issue 24, 183–186 (2012)
Keywords: radio telescope, crioelectronic radiometer, secondary mirror
About the paperAbstract
The new uncooled RATAN-600 radiometric system ERIDAN-2 ist presented. This is a result of reconstruction of it's previous version — receiving set ERIDAN with liquid nitrogen front-end cooling. The system receive three wavelength ranges: 1.4, 2.7 and 6.2 cm. After laboratory testing the radiometric set is in diagnostic operating at RATAN-600 secondary mirror Nr2. The first results of observations of radio sources are reported.
Citation
A. B. Berlin, N. A. Nizhelsky, P . G. Cybulev, D. V. Kratov, R. Yu. Udovitsky, B. I. Karabashev. Reconstruction of radiometric system "ERIDAN" // Transactions of IAA RAS. — 2012. — Issue 24. — P. 183–186.
@article{berlin2012,
abstract = {The new uncooled RATAN-600 radiometric system ERIDAN-2 ist presented. This is a result of reconstruction of it's previous version — receiving set ERIDAN with liquid nitrogen front-end cooling. The system receive three wavelength ranges: 1.4, 2.7 and 6.2 cm. After laboratory testing the radiometric set is in diagnostic operating at RATAN-600 secondary mirror Nr2. The first results of observations of radio sources are reported.},
author = {A.~B. Berlin and N.~A. Nizhelsky and P.~G. Cybulev and D.~V. Kratov and R.~Yu. Udovitsky and B.~I. Karabashev},
issue = {24},
journal = {Transactions of IAA RAS},
keyword = {radio telescope, crioelectronic radiometer, secondary mirror},
pages = {183--186},
title = {Reconstruction of radiometric system "ERIDAN"},
url = {http://iaaras.ru/en/library/paper/847/},
year = {2012}
}
TY - JOUR
TI - Reconstruction of radiometric system "ERIDAN"
AU - Berlin, A. B.
AU - Nizhelsky, N. A.
AU - Cybulev, P. G.
AU - Kratov, D. V.
AU - Udovitsky, R. Yu.
AU - Karabashev, B. I.
PY - 2012
T2 - Transactions of IAA RAS
IS - 24
SP - 183
AB - The new uncooled RATAN-600 radiometric system ERIDAN-2 ist presented.
This is a result of reconstruction of it's previous version —
receiving set ERIDAN with liquid nitrogen front-end cooling. The
system receive three wavelength ranges: 1.4, 2.7 and 6.2 cm. After
laboratory testing the radiometric set is in diagnostic operating at
RATAN-600 secondary mirror Nr2. The first results of observations of
radio sources are reported.
UR - http://iaaras.ru/en/library/paper/847/